| 4410 Series Elements |
| Table 9 - Full Scale Power and Frequency Ranges 0-10, 30, 100, 300 Milliwatts, 1, 3, 10 Watts |
|
MHz |
30-50 |
50-88 |
88-108 |
- |
150-250 |
225-400 |
400-800 |
800-900 |
900-1000 |
|
Model |
4410-20 |
4410-21 |
4410-27 |
- |
4410-23 |
4410-24 |
4410-25 |
4410-26 |
4410-28 | |
| |
| Table 9A - Full Scale Power and Frequency Ranges 0-10, 30, 100, 300 Milliwatts, 1, 3, 10, 30 Watts |
|
MHz |
864-868 |
917-970 |
|
Model |
4410-38 |
4410-29 |
|
Accuracy |
10% of reading accuracy on 100 mW, 300mW and 1 W, 5% on all other scales 5% 10 mW to 1 W only | |
| |
| Table 10 - Full Scale Power and Frequency Ranges 0-100, 300 Milliwatts,1, 3, 10, 30 Watts |
|
MHz |
25-80 |
50-125 |
100-250 |
200-500 |
400-1000 |
1000-1800 |
1800-2300 |
|
Model |
4410-10 |
4410-11 |
4410-12 |
4410-13 |
4410-14 |
4410-15* |
4410-16* |
| * Accuracy is ±8% of reading | |
| |
| Table 11 - Full-Scale Power and Frequency Ranges 0-1, 3, 10, 30, 100, 300, 1000 Watts |
|
MHz |
2-30 |
25-80 |
50-200 |
144-520 |
200-1000 |
|
Model |
4410-3 |
4410-5 |
4410-6 |
4410-7 |
4410-8 | |
| |
| Table 12 - Full-Scale Power and Frequency Ranges 0-10, 30, 100, 300, 1000, 3000, 10,000 Watts |
|
MHz |
0.2 - 0.535 |
0.45 - 2.5 |
2 - 30 |
|
Model |
4410-1 |
4410-2 |
4410-4 | | |
鸟牌功率计探头选型表
由深圳田诚电子提供

ELEMENT SELECTION GUIDE
|
Wattmeter Model |
Select Element from Table(s) |
|
3128A |
1, 2, 3, 3A, 4, 6, 14* |
|
3170A |
1, 2, 3, 3A, 4, 6, 14* |
|
43 |
1, 2, 3, 3A, 4, 6, 14* |
|
43P |
1, 2, 3, 3A, 4, 5, 6 |
|
4305A |
请看表①, 1 5/8AA |
|
4314B |
1, 2, 3, 3A, 4, 5, 6, 14* |
|
4391A |
1, 2, 3, 3A, 4, 5, 6, 14* |
|
4410A, 4412A |
请看表② |
|
4431 |
1, 2, 3, 3A, 4, 6, 14* |
|
4521, 4522 |
1, 2, 3, 3A, 4, 6, 14* |
|
4526 |
1, 2, 3, 3A, 4, 6, 14* |
|
4527 |
2 MHz to 512 MHz elements in 1,2, 6,14* |
* Table 14 describes coupler elements used for RF sampling. The instrument meter
does not read when these elements are installed, but simply serves as a line
section.
ELEMENT TABLE FREQUENCY & POWER LIMITS
|
ELEMENT
ABLET |
MIN. PWR
(WATTS F.S.) |
MAX. PWR
(WATTS F.S.) |
MIN. FREQ
(MHz) |
MAX. FREQ
(MHz) |
|
APM |
1 |
1000 |
2 |
2300 |
|
1 |
5 |
5000 |
2 |
1000 |
|
2 |
1 |
2.5 |
25 |
1000 |
|
3 |
1 |
250 |
950 |
2700 |
|
3A |
0.1 |
0.5 |
950 |
2600 |
|
4 |
1000 |
10000 |
0.45 |
2.5 |
|
5 |
500 |
10000 |
2 |
1260 |
|
6 |
0.1 |
0.5 |
45 |
1000 |
|
8 |
50 |
25,000 |
0.45 |
2300 |
|
9 |
0.01 |
10 |
30 |
1000 |
|
9A |
0.001 |
1 |
864 |
970 |
|
10 |
0.1 |
100 |
25 |
2300 |
|
11 |
1 |
1000 |
2 |
1000 |
|
12 |
10 |
10000 |
0.2 |
30 |
|
14 |
1000 |
1000 |
50 |
1250 |
TABLE 1 — STANDARD ELEMENT
|
|
Frequency Bands (MHz) |
| Power Range |
2-30 |
25-60 |
50-125 |
100-250 |
200-500 |
400-1000 |
|
5 W |
— |
5A |
5B |
5C |
5D |
5E |
|
10 W |
— |
10A |
10B |
10C |
10D |
10E |
|
25 W |
— |
25A |
25B |
25C |
25D |
25E |
|
50 W |
50H |
50A |
50B |
50C |
50D |
50E |
|
100 W |
100H |
100A |
100B |
100C |
100D |
100E |
|
250 W |
250H |
250A |
250B |
250C |
250D |
250E |
|
500 W |
500H |
500A |
500B |
500C |
500D |
500E |
|
1000 W |
1000H |
1000A |
1000B |
1000C |
1000D |
1000E |
|
2500 W |
2500H |
— |
— |
— |
— |
— |
|
5000 W |
5000H |
— |
— |
— |
— |
— |
TABLE 2 — LOW-POWER ELEMENTS
|
1 Watt |
|
|
Frequency (MHz) |
40-
50 |
50-
60 |
60-
80 |
80-
90 |
95-
125 |
110-
160 |
150-
250 |
200-
300 |
275-
450 |
425-
850 |
800-
1000 |
|
Part Number |
040-
1 |
050-
1 |
060-
1 |
080-
1 |
095-
1 |
110-
1 |
150-
1 |
200-
1 |
275-
1 |
425-
1 |
801-
1 |
|
2.5 Watt |
|
|
Frequency (MHz) |
25-
30 |
30-
40 |
40-
50 |
50-
60 |
60-
80 |
80-
95 |
95-
150 |
150-
250 |
200-
300 |
250-
450 |
400-
850 |
800-
1000 |
|
Part Number |
025-
2 |
030-
2 |
040-
2 |
050-
2 |
060-
2 |
080-
2 |
095-
2 |
150-
2 |
200-
2 |
250-
2 |
400-
2 |
801-
2 |
TABLE 3 — HIGH-FREQUENCY ELEMENTS, ENTIRE TABLE ±8% FS
|
|
Frequency Bands (MHz) |
|
Power Range |
950-
1260 |
1100-
1800 |
1700-
1990 |
1990-
2200 |
2200-
2300 |
2300-
2400 |
2400-
2500 |
2500-
2600 |
2600-
2700 |
|
1 W |
1J |
1K |
1L1 |
1L2 |
1M |
431-
17 |
431-
20 |
431-
23 |
431-
120 |
|
2.5 W |
2.5J |
2.5K |
2.5L1 |
2.5L2 |
2.5M |
431-
110 |
431-
107 |
431-
108 |
431-
117 |
|
5 W |
5J |
5K |
5L1 |
5L2 |
5M |
432-
15 |
432-
28 |
432-
2 |
432-
12 |
|
10 W |
10J |
10K |
10L1 |
10L2 |
10M |
432-
125 |
432-
141 |
432-
102 |
432-
104 |
|
25 W |
25J |
25K |
25L1 |
25L2 |
25M |
433-
19 |
433-
20 |
433-
35 |
433-
36 |
|
50 W |
50J |
50K |
50L1 |
50L2 |
50M |
433-
37 |
433-
38 |
433-
163 |
433-
164 |
|
100 W |
100J
|
— |
— |
— |
— |
— |
— |
— |
— |
|
250 W |
250J
|
— |
— |
— |
— |
— |
— |
— |
— |
TABLE 3A — HIGH FREQUENCY MILLIWATT ELEMENTS
|
|
Frequency Bands (MHz) |
|
Power Range |
950-
1260 |
1250-
1500 |
1500-
1700 |
1700-
2200 |
2300-
2400 |
2400-
2500 |
2500-
2600 |
|
100 mW |
430-
82 |
430-
209 |
430-
210 |
430-
178 |
430-
211 |
430-
182 |
— |
|
250 mW |
— |
— |
— |
430-
1 |
430-
239 |
430-
240 |
430-
241 |
|
500 mW |
— |
430-
259 |
— |
430-
95 |
— |
430-
159 |
— |
TABLE 4 — LOW-FREQUENCY ELEMENTS
|
Frequency Band
|
|
Power Range |
.45 - 2.5 MHz |
|
1000 W |
1000P |
|
2500 W |
2500P |
|
5000 W |
5000P |
|
10000 W |
10000P |
TABLE 5 — PULSE-POWER ELEMENTS, ENTIRE TABLE ±8% OF FULL SCALE
|
Frequency Bands (MHz)
|
|
Power Range |
2-30 |
25-60 |
50-125 |
100-250 |
400-1000 |
950-1260 |
|
500 W |
— |
— |
— |
— |
— |
500J |
|
1000 W |
— |
— |
— |
— |
— |
1000J |
|
2500 W |
— |
2500A |
2500B |
2500C |
2500E |
2500J |
|
5000 W |
— |
5000A |
5000B |
5000C |
5000E |
5000J |
|
10000 W |
10000H |
— |
10000B |
— |
10000E |
— |
Elements 500 - 1000 Watts, 950 - 1260 MHz, are rated at 100 Watts avg.
Elements 2500 Watts and higher, 25-1000 MHz, are rated at 1000 Watts avg. Elements are capable of reading peak and average power.
鸟牌功率计探头选型表 由深圳田诚电子提供
TABLE 6 — MILLIWATT ELEMENTS
|
100 mW |
|
Frequency (MHz) |
45-
50 |
72-
76 |
108-
136 |
135-
175 |
320-
340 |
328-
336 |
400-
420 |
420-
450 |
450-
470 |
600-
800 |
800-
1000 |
|
Cat. No. |
430-
266 |
430-
2 |
430-
57 |
430-
86 |
430-
205 |
430-
3 |
430-
7 |
430-
208 |
430-
8 |
430-
169 |
430-
263 |
|
250 mW |
|
Frequency (MHz) |
72-
76 |
88-
108 |
105-
120 |
116-
126 |
130-
150 |
190-
210 |
450-
470 |
800-
1000 |
|
Cat. No. |
430-
22 |
430-
217 |
430-
20 |
430-
48 |
430-
13 |
430-
65 |
430-
61 |
430-
264 |
|
500 mW |
|
Frequency (MHz) |
72-
76 |
88-
108 |
105-
120 |
120-
136 |
136-
150 |
240-
290 |
290-
340 |
340-
360 |
350-
400 |
400-
450 |
450-
500 |
600-
800 |
800-
1000 |
|
Cat. No. |
430-
33 |
430-
247 |
430-
26 |
430-
248 |
430-
249 |
430-
27 |
430-
253 |
430-
157 |
430-
254 |
430-
255 |
430-
256 |
430-
258 |
430-
265 |
NONDIRECTIONAL SAMPLER ELEMENTS FOR QC-TYPE OR 7/8" EIA LINE
|
Frequency Band (MHz) |
Nominal Coupling |
Max. Main Line Power |
Model |
|
25-1000 |
-50 dB ± 2 dB
(-66 dB @ 2 MHz) |
500W |
4274-025 |
|
100-400 |
-35 to -48 dB (±1 dB) Adjustable |
500W |
4274-050 |
TABLE 14 — DIRECTIONAL COUPLER ELEMENTS
FOR QC-TYPE OR 7/8" EIA LINE
|
Frequency
Band (MHz) |
Nominal
Coupling |
Max. Main
Line Power |
Model |
|
50-100 |
-40 dB |
1 kW |
400-50 |
|
75-150 |
-40 dB |
1 kW |
400-75 |
|
125-250 |
-40 dB |
1 kW |
400-125 |
|
225-450 |
-40 dB |
1 kW |
400-225 |
|
400-800 |
-40 dB |
1 kW |
400-400 |
|
750-1250 |
-40 dB |
1 kW |
400-750 |
TABLE 1 5/8AA — STANDARD ELEMENTS 30 uA
|
|
Frequency Bands (MHz) |
|
Power Range |
2-30 |
50-125 |
100-250 |
400-1000 |
|
100 W |
— |
100B12 |
100C12 |
100E12 |
|
250 W |
— |
250B12 |
250C12 |
250E12 |
|
500 W |
500H12 |
500B12 |
500C12 |
500E12 |
|
1000 W |
1000H12 |
1000B12 |
1000C12 |
1000E12 |
|
2500 W |
2500H12 |
2500B12 |
2500C12 |
2500E12 |
|
5000 W |
5000H12 |
5000B12 |
5000C12 |
5000E12 |
|
10 kW |
10KH12 |
10KB12 |
— |
— |
|
25 kW |
25KH12 |
25KB12 |
— |
— |
表① 4305A Elements
| |
Frequency (MHz) |
|
Power |
.45-2.5 |
2–30 |
50-125 |
100-250 |
400-1000 |
1100-1800 |
|
50 W |
— |
— |
— |
— |
— |
50K7 |
|
2500 W |
— |
— |
2500B7 |
2500C7 |
2500E7 |
— |
|
5000 W |
— |
— |
5000B7 |
— |
— |
— |
|
10 kW |
— |
10KH7 |
— |
— |
— |
— |
|
25 kW |
25KP7 |
— |
— |
— |
— |
— |
表② 4410 Elements
Table 9 - Full-Scale Power and Frequency Ranges 0-10, 30, 100, 300
Milliwatts, 1, 3, 10 Watts
|
MHz |
30-
50 |
50-
88 |
88-
108 |
- |
150-
250 |
225-
400 |
400-
800 |
800-
900 |
900-
1000 |
|
Model |
4410-
20 |
4410-
21 |
4410-
27 |
- |
4410-
23 |
4410-
24 |
4410-
25 |
4410-
26 |
4410-
28 |
Table 10 - Full-Scale Power and Frequency Ranges 0-100, 300 Milliwatts,
1, 3, 10, 30, 100 Watts
|
MHz |
25-
80 |
50-
125 |
100-
250 |
200-
500 |
400-
1000 |
1000-
1800 |
1800-
2300 |
|
Model |
4410-
10 |
4410-
11 |
4410-
12 |
4410-
13 |
4410-
14 |
4410-
15* |
4410-
16* |
Table 11 - Full-Scale Power and Frequency Ranges 0-1, 3, 10, 30, 100, 300,
1000 Watts
|
MHz |
2–30 |
25-80 |
50-200 |
144-520 |
200-1000 |
|
Model |
4410-3 |
4410-5 |
4410-6 |
4410-7 |
4410-8 |
Table 12 - Full-Scale Power and Frequency Ranges 0-10, 30, 100, 300, 1000,
3000, 10,000 Watts
|
MHz |
0.2-0.535 |
0.45-2.5 |
2-30 |
|
Model |
4410-1 |
4410-2 |
4410-4 |
* Accuracy is ±8% of reading 鸟牌功率计探头选型表 由深圳田诚电子提供 |